creation and initialization now happens in python. Parameter objects
are generated and initialized by python. The .ini file is now solely for
debugging purposes and is not used in construction of the objects in any
way.
--HG--
extra : convert_revision : 7e722873e417cb3d696f2e34c35ff488b7bff4ed
Move check for loops outside, since half the call sites
end up working around it anyway. Return integer port ID
instead of port object pointer.
--HG--
extra : convert_revision : 4c31fe9930f4d1aa4919e764efb7c50d43792ea3
Note that we should *not* print pointer values in DPRINTFs as
these needlessly clutter tracediff output.
--HG--
extra : convert_revision : 25a448f1b3ac8d453a717a104ad6dc0112fb30bb
into vm1.(none):/home/stever/bk/newmem-cache2
configs/example/memtest.py:
Hand merge redundant changes.
--HG--
extra : convert_revision : a2e36be254bf052024f37bcb23b5209f367d37e1
timing mode still broken.
configs/example/memtest.py:
Revamp options.
src/cpu/memtest/memtest.cc:
No need for memory initialization.
No need to make atomic response... memory system should do that now.
src/cpu/memtest/memtest.hh:
MemTest really doesn't want to snoop.
src/mem/bridge.cc:
checkFunctional() cleanup.
src/mem/bus.cc:
src/mem/bus.hh:
src/mem/cache/base_cache.cc:
src/mem/cache/base_cache.hh:
src/mem/cache/cache.cc:
src/mem/cache/cache.hh:
src/mem/cache/cache_blk.hh:
src/mem/cache/cache_builder.cc:
src/mem/cache/cache_impl.hh:
src/mem/cache/coherence/coherence_protocol.cc:
src/mem/cache/coherence/coherence_protocol.hh:
src/mem/cache/coherence/simple_coherence.hh:
src/mem/cache/miss/SConscript:
src/mem/cache/miss/mshr.cc:
src/mem/cache/miss/mshr.hh:
src/mem/cache/miss/mshr_queue.cc:
src/mem/cache/miss/mshr_queue.hh:
src/mem/cache/prefetch/base_prefetcher.cc:
src/mem/cache/tags/fa_lru.cc:
src/mem/cache/tags/fa_lru.hh:
src/mem/cache/tags/iic.cc:
src/mem/cache/tags/iic.hh:
src/mem/cache/tags/lru.cc:
src/mem/cache/tags/lru.hh:
src/mem/cache/tags/split.cc:
src/mem/cache/tags/split.hh:
src/mem/cache/tags/split_lifo.cc:
src/mem/cache/tags/split_lifo.hh:
src/mem/cache/tags/split_lru.cc:
src/mem/cache/tags/split_lru.hh:
src/mem/packet.cc:
src/mem/packet.hh:
src/mem/physical.cc:
src/mem/physical.hh:
src/mem/tport.cc:
More major reorg. Seems to work for atomic mode now,
timing mode still broken.
--HG--
extra : convert_revision : 7e70dfc4a752393b911880ff028271433855ae87
using a divide in order to not loop forever after resuming from a checkpoint
--HG--
extra : convert_revision : 4bbc70b1be4e5c4ed99d4f88418ab620d5ce475a
Compiles but doesn't work... committing just so I can merge
(stupid bk!).
src/mem/bridge.cc:
Get rid of SNOOP_COMMIT.
src/mem/bus.cc:
src/mem/packet.hh:
Get rid of SNOOP_COMMIT & two-pass snoop.
First bits of EXPRESS_SNOOP support.
src/mem/cache/base_cache.cc:
src/mem/cache/base_cache.hh:
src/mem/cache/cache.hh:
src/mem/cache/cache_impl.hh:
src/mem/cache/miss/blocking_buffer.cc:
src/mem/cache/miss/miss_queue.cc:
src/mem/cache/prefetch/base_prefetcher.cc:
Big reorg of ports and port-related functions & events.
src/mem/cache/cache.cc:
src/mem/cache/cache_builder.cc:
src/mem/cache/coherence/SConscript:
Get rid of UniCoherence object.
--HG--
extra : convert_revision : 7672434fa3115c9b1c94686f497e57e90413b7c3
figure out the block size from devices attached to the bus otherwise use a default block size when no devices that care are attached
configs/common/FSConfig.py:
src/mem/bridge.cc:
src/mem/bridge.hh:
src/python/m5/objects/Bridge.py:
fix partial writes with a functional memory hack
src/mem/bus.cc:
src/mem/bus.hh:
src/python/m5/objects/Bus.py:
figure out the block size from devices attached to the bus otherwise use a default block size when no devices that care are attached
src/mem/packet.cc:
fix WriteInvalidateResp to not be a request that needs a response since it isn't
src/mem/port.hh:
by default return 0 for deviceBlockSize instead of panicing. This makes finding the block size the bus should use easier
--HG--
extra : convert_revision : 3fcfe95f9f392ef76f324ee8bd1d7f6de95c1a64
In this way a MemoryObject can keep a functional port around and give it to anyone who wants to do functional accesses rather
than creating a new one each time.
src/mem/bus.cc:
src/mem/bus.hh:
src/mem/cache/cache_impl.hh:
only keep around one func port we give to anyone who wants it. Otherwise we can run out of port ids reasonably quickly if
a lot of functional accesses are happening (e.g. remote debugging, dprintk, etc)
--HG--
extra : convert_revision : 6a9e3e96f51cedaab6de1b36cf317203899a3716
into zamp.eecs.umich.edu:/z/ktlim2/clean/tmp/clean2
src/cpu/base_dyn_inst.hh:
Hand merge. Line is no longer needed because it's handled in the ISA.
--HG--
extra : convert_revision : 0be4067aa38759a5631c6940f0167d48fde2b680
1. Update packet's flags properly when a snoop happens
2. Don't allow accesses to read a block's data if the block has outstanding MSHRs. This avoids a RAW hazard in MP systems that the memory system was not detecting properly earlier (a write required a block to upgrade, and while the upgrade was outstanding, a read came along and read old data).
3. Update MSHR's request upon a response being handled. If the MSHR has more targets than it can respond to in one cycle, then its request must be properly updated to the new head of the targets list.
src/mem/bus.cc:
Update packet's flags properly upon snoop.
src/mem/cache/cache_impl.hh:
Be sure to not allow accesses to a block with outstanding MSHRs.
src/mem/cache/miss/miss_queue.cc:
Update MSHR's request upon a response being handled.
--HG--
extra : convert_revision : 76a9abc610ca3f1904f075ad21637148a41982d6
don't create a new physPort/virtPort every time activateContext() is called
add the ability to tell a memory object to delete it's reference to a port and a method to have a port call deletePortRefs()
on the port owner as well as delete it's peer
still need to stop calling connectMemoPorts() every time activateContext() is called or we'll overflow the bus id and panic
src/cpu/thread_state.cc:
if we hav ea (phys|virt)Port don't create a new on, have it delete it's peer and then reuse it
src/mem/bus.cc:
src/mem/bus.hh:
add ability to delete a port by usig a hash_map instead of an array to store port ids
add a function to do deleting
src/mem/cache/cache.hh:
src/mem/cache/cache_impl.hh:
src/mem/mem_object.cc:
src/mem/mem_object.hh:
adda function to delete port references from a memory object
src/mem/port.cc:
src/mem/port.hh:
add a removeConn function that tell the owener to delete any references to the port and then deletes its peer
--HG--
extra : convert_revision : 272f0c8f80e1cf1ab1750d8be5a6c9aa110b06a4
Fix a small writeback bug when missing in the L2 in atomic mode
src/mem/bus.cc:
Fix a comment to make sense
src/mem/cache/cache_impl.hh:
Do a functional access to levels above on a read as a temporary solution for L2's in FS
Also fix a small writeback miss in L2 issue
src/mem/cache/coherence/simple_coherence.hh:
src/mem/cache/coherence/uni_coherence.cc:
src/mem/cache/coherence/uni_coherence.hh:
Do a functional access to levels above on a read as a temporary solution for L2's in FS
tests/quick/00.hello/ref/alpha/linux/o3-timing/m5stats.txt:
tests/quick/00.hello/ref/alpha/linux/simple-timing/m5stats.txt:
tests/quick/01.hello-2T-smt/ref/alpha/linux/o3-timing/m5stats.txt:
Update ref's for writeback changes
--HG--
extra : convert_revision : 937febd577b16b7fd97a5a68acaf53541828a251
src/mem/bus.cc:
Make it so that invalidates being sent from the responder up don't call the responder
but they should also not Panic.
src/mem/packet.hh:
If we don't have data in the packet, don't call deleteData:
Example: InvalidateRequests never have data.
--HG--
extra : convert_revision : 18766bc9f3bb4d852ac651d094254d347abd1634
src/mem/bridge.cc:
Update brdiges, now that snoop addresses are properly forwarded.
Bus bridge should only handle snoops on the second phase (SNOOP_COMMIT)
src/mem/bus.cc:
src/mem/bus.hh:
Make sure if a busBridge has access to both things that snoop and things that respond it only takes the request once
--HG--
extra : convert_revision : 26cc9ee4429be45d4476fa435e0e9a54843c2509
src/mem/bus.cc:
Only call snoop once per port, need to fix it so snoop ranges that overlap aren't added to list
Functional accesses that call snoop and it goes to a higher bus may change the src, reset it after each snoop.
--HG--
extra : convert_revision : 7276059c798a85cb9d138ccc5531298ecd055c13
src/mem/bus.cc:
Actually return the snoop list when asked for it.
Don't get stuck in infinite functional loops
--HG--
extra : convert_revision : 8e6dafbd10b30d48d28b6b5d4b464e8e8f6a3ddc
src/cpu/o3/cpu.cc:
Handle draining properly when CPU isn't actually being used.
src/cpu/simple/atomic.cc:
Be sure to set status properly when draining.
src/mem/bus.cc:
Fix for draining.
--HG--
extra : convert_revision : d9796e6693e974f022159029fc9743c49a970c8f
src/mem/bus.cc:
Fix up draining to work properly.
src/mem/bus.hh:
Initialize drainEvent to NULL.
src/mem/cache/base_cache.cc:
src/mem/cache/base_cache.hh:
Add draining to the caches.
--HG--
extra : convert_revision : 3082220a75d50876f10909f9f99bec535889f818
src/mem/bus.cc:
src/mem/bus.hh:
Bus now will be setup with a default responder, unless the user overrides it. This default responder should return BadAddress if no matching port is found.
src/python/m5/objects/Bus.py:
Bus now has a default responder for FS mode if the user doesn't override it. It returns BadAddress if no matching port is found.
src/python/m5/objects/Tsunami.py:
Add bad address device. Also record when the user has specified their own default responder.
--HG--
extra : convert_revision : 59070477ae313ee711b2d59baa2369c9a91c5b85
Fix a segfault associated with DefaultId
src/mem/bus.cc:
Handle a segfault in the bus when DefaultPort was being used
src/mem/bus.hh:
Make the Default ID more unique (it overlapped with Broadcast ID)
--HG--
extra : convert_revision : 9182805c5cf4d9fe004e6c5be8547a8f41ed7bfe
src/mem/bus.cc:
Add debugging statement
src/mem/bus.hh:
Fix implementation of bus for subsequent recvTimings while handling a retry request.
src/mem/tport.cc:
Rework timing port to retry properly
--HG--
extra : convert_revision : fbfb5e8b4a625e49c6cd764da1df46a4f336b1b2
src/cpu/memtest/memtest.cc:
src/cpu/memtest/memtest.hh:
Make Memtester able to test atomic as well
src/mem/bus.cc:
src/mem/bus.hh:
Handle atomic snoops properly for cache->cache transfers
src/mem/cache/cache_impl.hh:
Debug output.
Clean up memleak in atomic mode.
Set hitLatency.
Still need to send back reasonable number for atomic return value.
src/mem/packet.cc:
Add command strings for new commands
src/python/m5/objects/MemTest.py:
Add param to test atomic memory.
--HG--
extra : convert_revision : 43f880e29215776167c16ea90793ebf8122c785b
src/base/traceflags.py:
Add new flags for cacheport
src/mem/bus.cc:
Add debugging info
src/mem/cache/base_cache.cc:
Add debuggin info
--HG--
extra : convert_revision : a6c4b452466a8e0b50a86e886833cb6e29edc748
src/mem/bus.cc:
Put back the check to see if the bus is busy. Also, populate the fields in the packet to indicate when the first word and the entire packet will be delivered.
src/mem/bus.hh:
Remove the occupyBus function.
src/mem/packet.hh:
Added fields to the packet to indicate when the first chunk of a packet arrives, and when the entire packet arrives.
--HG--
extra : convert_revision : cfc7670a33913d48a04d02c6d2448290a51f2d3c
src/mem/bus.cc:
Fixes to the previous hand merging, and put the snooping back into recvTiming and out of it's own function.
src/mem/bus.hh:
Put snooping back into recvTiming and not in it's own function.
--HG--
extra : convert_revision : fd031b7e6051a5be07ed6926454fde73b1739dc6
If the cpu needs to update any state when it gets a functional write (LSQ??)
then that code needs to be written.
src/cpu/o3/fetch_impl.hh:
src/cpu/o3/lsq_impl.hh:
src/cpu/ozone/front_end_impl.hh:
src/cpu/ozone/lw_lsq_impl.hh:
src/cpu/simple/atomic.cc:
src/cpu/simple/timing.cc:
CPU's can recieve functional accesses, they need to determine if they need to do anything with them.
src/mem/bus.cc:
src/mem/bus.hh:
Make the fuctional path do the correct tye of snoop
--HG--
extra : convert_revision : 70d09f954b907a8aa9b8137579cd2b06e02ae2ff
into zeep.eecs.umich.edu:/home/gblack/m5/newmem_bus
src/mem/bus.cc:
Hand merged. Needs to be fixed
--HG--
extra : convert_revision : df03219ccfd18431cc726a063bd29d30554944a1
src/mem/bus.cc:
src/mem/bus.hh:
minor fix and some formatting changes
src/python/m5/objects/Bus.py:
changed bits to bytes
--HG--
extra : convert_revision : dcd22205604b7a2727eaf2094084c4858f3589c5
Still need:
-Handle NACK's on the recieve side
-Distinguish top level caches
-Handle repsonses from caches failing the fast path
-Handle BusError and propogate it
-Fix the invalidate packet associated with snooping in the cache
src/mem/bus.cc:
Make sure to snoop on functional accesses
src/mem/cache/base_cache.cc:
Wait to make a request into a response until it is ready to be issued
src/mem/cache/base_cache.hh:
Support range changes for snoops
Set up snoop responses for cache->cache transfers
src/mem/cache/cache_impl.hh:
Only access the cache if it wasn't satisfied by cache->cache transfer
Handle snoop phases (detect block, then snoop)
Fix functional access to work properly (still need to fix snoop path for functional accesses)
--HG--
extra : convert_revision : 4c25f11d7a996c1f56f4f7b55dde87a344e5fdf8
Working on pulling out the changes in the cache so that it remains working.
src/mem/bus.cc:
Changes for multi-phase snoop
Some code for registering snoop ranges (a version that compiles and runs, but does nothing)
src/mem/bus.hh:
Changes for multi-phase snoop
src/mem/packet.hh:
Flag for multi-phase snoop
src/mem/port.hh:
Status for multi-phase snoop
--HG--
extra : convert_revision : 4c2e5263bba16e3bcf03aabe36ff45ec36de4720
Update configuration for new default responder on bus
Update to devices to handle their own pci config space without pciconfigall
Remove most of pciconfigall, it now is a dumbdevice which gets it's address based on the bus it's supposed to respond for
Remove need for pci config space from platform, add registerPciDevice function to prevent more than one device from having same
bus:dev:func and interrupt
Remove pciconfigspace from pci devices, and py files
Add calcConfigAddr that returns address for config space based on bus/dev/function + offset
configs/test/fs.py:
Update configuration for new default responder on bus
src/dev/ide_ctrl.cc:
src/dev/ide_ctrl.hh:
src/dev/ns_gige.cc:
src/dev/ns_gige.hh:
src/dev/pcidev.cc:
src/dev/pcidev.hh:
Update to handle it's own pci config space without pciconfigall
src/dev/io_device.cc:
src/dev/io_device.hh:
change naming for pio port
break out recvTiming into two functions to reuse code
src/dev/pciconfigall.cc:
src/dev/pciconfigall.hh:
removing most of pciconfigall, it now is a dumbdevice which gets it's address based on the bus it's supposed to respond for
src/dev/pcireg.h:
add a max size for PCI config space (per PCI spec)
src/dev/platform.cc:
src/dev/platform.hh:
remove need for pci config space from platform, add registerPciDevice function to prevent more than one device from having same
bus:dev:func and interrupt
src/dev/sinic.cc:
remove pciconfigspace as it's no longer a needed parameter
src/dev/tsunami.cc:
src/dev/tsunami.hh:
src/dev/tsunami_pchip.cc:
src/dev/tsunami_pchip.hh:
add calcConfigAddr that returns address for config space based on bus/dev/function + offset (per PCI spec)
src/mem/bus.cc:
src/mem/bus.hh:
src/python/m5/objects/Bus.py:
add idea of default responder to bus
src/python/m5/objects/Pci.py:
add config port for pci devices
add latency, bus and size parameters for pci config all (min is 8MB, max is 256MB see pci spec)
--HG--
extra : convert_revision : 99db43b0a3a077f86611d6eaff6664a3885da7c9
into Python.
Add Port and VectorPort objects and support for
specifying port connections via assignment.
The whole C++ ConfigNode hierarchy is gone now, as are
C++ Connector objects.
configs/test/fs.py:
configs/test/test.py:
Rewrite for new port connector syntax.
src/SConscript:
Remove unneeded files:
- mem/connector.*
- sim/config*
src/dev/io_device.hh:
src/mem/bridge.cc:
src/mem/bridge.hh:
src/mem/bus.cc:
src/mem/bus.hh:
src/mem/mem_object.hh:
src/mem/physical.cc:
src/mem/physical.hh:
Allow getPort() to take an optional index to
support vector ports (eventually).
src/python/m5/__init__.py:
Move SimObject construction and port connection
operations into Python (with C++ calls).
src/python/m5/config.py:
Move SimObject construction and port connection
operations into Python (with C++ calls).
Add support for declaring and connecting MemObject
ports in Python.
src/python/m5/objects/Bus.py:
src/python/m5/objects/PhysicalMemory.py:
Add port declaration.
src/sim/builder.cc:
src/sim/builder.hh:
src/sim/serialize.cc:
src/sim/serialize.hh:
ConfigNodes are gone; builder just gets the
name of a .ini file section now.
src/sim/main.cc:
Move SimObject construction and port connection
operations into Python (with C++ calls).
Split remaining initialization operations into two parts,
loadIniFile() and finalInit().
src/sim/param.cc:
src/sim/param.hh:
SimObject resolution done globally in Python now
(not via ConfigNode hierarchy).
src/sim/sim_object.cc:
Remove unneeded #include.
--HG--
extra : convert_revision : 2fa4001eaaec0c9a4231ef6e854f8e156d930dfe
it ends up being O(N^2). But it's probably going to have to change for the real bus anyway, so it should be rewritten then
Change recvRetry() to not accept a packet. Sendtiming should be called again (and can respond with false or true)
Removed Port Blocked/Unblocked and replaced with sendRetry().
Remove possibility of packet mangling if packet is going to be refused anyway in bridge
src/cpu/simple/atomic.cc:
src/cpu/simple/atomic.hh:
src/cpu/simple/timing.cc:
src/cpu/simple/timing.hh:
Change recvRetry() to not accept a packet. Sendtiming should be called again (and can respond with false or true)
src/dev/io_device.cc:
src/dev/io_device.hh:
Make DMA Timing requests/responses work.
Change recvRetry() to not accept a packet. Sendtiming should be called again (and can respond with false or true)
src/mem/bridge.cc:
src/mem/bridge.hh:
Change recvRetry() to not accept a packet. Sendtiming should be called again (and can respond with false or true)
Removed Port Blocked/Unblocked and replaced with sendRetry().
Remove posibility of packet mangling if packet is going to be refused anyway.
src/mem/bus.cc:
src/mem/bus.hh:
Add a very poor implementation of dealing with retries on timing requests. It is especially slow with tracing on since
it ends up being O(N^2). But it's probably going to have to change for the real bus anyway, so it should be rewritten then
src/mem/port.hh:
Change recvRetry() to not accept a packet. Sendtiming should be called again (and can respond with false or true)
Removed Blocked/Unblocked port status, their functionality is really duplicated in the recvRetry() method
--HG--
extra : convert_revision : fab613404be54bfa7a4c67572bae7b559169e573
src/base/traceflags.py:
Sort flags so you can find things.
Add BusAddrRanges flag for tracking RangeChange events
separately from general bus activity.
src/mem/bus.cc:
Add BusAddrRanges flag for tracking RangeChange events
separately from general bus activity.
src/mem/port.cc:
src/mem/port.hh:
Print Config trace message when peers are set up.
--HG--
extra : convert_revision : d7c11d5f90c8de5c8d97e473501a268a567e9e44
- new constructor guarantees initialization of most fields
- flags track status of non-guaranteed fields (addr, size, src)
- accessor functions (getAddr() etc.) check status on access
- Command & Result classes are nested in Packet class scope
- Command now built from vector of behavior bits
- string version of Command for tracing
- reinitFromRequest() and makeTimingResponse() encapsulate
common manipulations of existing packets
src/cpu/simple/atomic.cc:
src/cpu/simple/base.cc:
src/cpu/simple/timing.cc:
src/dev/alpha_console.cc:
src/dev/ide_ctrl.cc:
src/dev/io_device.cc:
src/dev/io_device.hh:
src/dev/isa_fake.cc:
src/dev/ns_gige.cc:
src/dev/pciconfigall.cc:
src/dev/sinic.cc:
src/dev/tsunami_cchip.cc:
src/dev/tsunami_io.cc:
src/dev/tsunami_pchip.cc:
src/dev/uart8250.cc:
src/mem/bus.cc:
src/mem/bus.hh:
src/mem/physical.cc:
src/mem/port.cc:
src/mem/port.hh:
src/mem/request.hh:
Update for new Packet interface.
--HG--
extra : convert_revision : 9973d09ea4fa61795f23772a7d3995fa4df5c269
Need to rewrite bus bridge to get any further.
src/dev/io_device.cc:
Set packet dest on timing responses.
src/mem/bus.cc:
Fix dest addr bounds check assertion.
Add assertion to catch infinite loopbacks.
src/mem/physical.cc:
Add comment.
--HG--
extra : convert_revision : 419b65a3a61e2d099884dbda117b338dffd80896