2016-07-21 18:19:16 +02:00
|
|
|
# Copyright (c) 2016 ARM Limited
|
|
|
|
# All rights reserved.
|
|
|
|
#
|
|
|
|
# The license below extends only to copyright in the software and shall
|
|
|
|
# not be construed as granting a license to any other intellectual
|
|
|
|
# property including but not limited to intellectual property relating
|
|
|
|
# to a hardware implementation of the functionality of the software
|
|
|
|
# licensed hereunder. You may use the software subject to the license
|
|
|
|
# terms below provided that you ensure that this notice is replicated
|
|
|
|
# unmodified and in its entirety in all distributions of the software,
|
|
|
|
# modified or unmodified, in source code or in binary form.
|
|
|
|
#
|
|
|
|
# Redistribution and use in source and binary forms, with or without
|
|
|
|
# modification, are permitted provided that the following conditions are
|
|
|
|
# met: redistributions of source code must retain the above copyright
|
|
|
|
# notice, this list of conditions and the following disclaimer;
|
|
|
|
# redistributions in binary form must reproduce the above copyright
|
|
|
|
# notice, this list of conditions and the following disclaimer in the
|
|
|
|
# documentation and/or other materials provided with the distribution;
|
|
|
|
# neither the name of the copyright holders nor the names of its
|
|
|
|
# contributors may be used to endorse or promote products derived from
|
|
|
|
# this software without specific prior written permission.
|
|
|
|
#
|
|
|
|
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
|
|
|
|
# "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
|
|
|
|
# LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
|
|
|
|
# A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
|
|
|
|
# OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
|
|
|
|
# SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
|
|
|
|
# LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
|
|
|
|
# DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
|
|
|
|
# THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
|
|
|
|
# (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
|
|
|
|
# OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
|
|
|
#
|
|
|
|
# Authors: Andreas Sandberg
|
|
|
|
# Gabor Dozsa
|
|
|
|
|
|
|
|
# System components used by the bigLITTLE.py configuration script
|
|
|
|
|
|
|
|
import m5
|
|
|
|
from m5.objects import *
|
|
|
|
m5.util.addToPath('../../common')
|
|
|
|
from Caches import *
|
2016-09-15 19:00:59 +02:00
|
|
|
import CpuConfig
|
2016-07-21 18:19:16 +02:00
|
|
|
|
|
|
|
class L1I(L1_ICache):
|
|
|
|
hit_latency = 1
|
|
|
|
response_latency = 1
|
|
|
|
mshrs = 4
|
|
|
|
tgts_per_mshr = 8
|
|
|
|
size = '48kB'
|
|
|
|
assoc = 3
|
|
|
|
|
|
|
|
|
|
|
|
class L1D(L1_DCache):
|
|
|
|
hit_latency = 2
|
|
|
|
response_latency = 1
|
|
|
|
mshrs = 16
|
|
|
|
tgts_per_mshr = 16
|
|
|
|
size = '32kB'
|
|
|
|
assoc = 2
|
|
|
|
write_buffers = 16
|
|
|
|
|
|
|
|
|
|
|
|
class WalkCache(PageTableWalkerCache):
|
|
|
|
hit_latency = 4
|
|
|
|
response_latency = 4
|
|
|
|
mshrs = 6
|
|
|
|
tgts_per_mshr = 8
|
|
|
|
size = '1kB'
|
|
|
|
assoc = 8
|
|
|
|
write_buffers = 16
|
|
|
|
|
|
|
|
|
|
|
|
class L2(L2Cache):
|
|
|
|
hit_latency = 12
|
|
|
|
response_latency = 5
|
|
|
|
mshrs = 32
|
|
|
|
tgts_per_mshr = 8
|
|
|
|
size = '1MB'
|
|
|
|
assoc = 16
|
|
|
|
write_buffers = 8
|
|
|
|
clusivity='mostly_excl'
|
|
|
|
|
|
|
|
|
|
|
|
class L3(Cache):
|
|
|
|
size = '16MB'
|
|
|
|
assoc = 16
|
|
|
|
hit_latency = 20
|
|
|
|
response_latency = 20
|
|
|
|
mshrs = 20
|
|
|
|
tgts_per_mshr = 12
|
|
|
|
clusivity='mostly_excl'
|
|
|
|
|
|
|
|
|
|
|
|
class MemBus(SystemXBar):
|
|
|
|
badaddr_responder = BadAddr(warn_access="warn")
|
|
|
|
default = Self.badaddr_responder.pio
|
|
|
|
|
|
|
|
|
2016-09-15 19:00:59 +02:00
|
|
|
class CpuCluster(SubSystem):
|
|
|
|
def __init__(self, system, num_cpus, cpu_clock, cpu_voltage,
|
|
|
|
cpu_type, l1i_type, l1d_type, wcache_type, l2_type):
|
|
|
|
super(CpuCluster, self).__init__()
|
|
|
|
self._cpu_type = cpu_type
|
|
|
|
self._l1i_type = l1i_type
|
|
|
|
self._l1d_type = l1d_type
|
|
|
|
self._wcache_type = wcache_type
|
|
|
|
self._l2_type = l2_type
|
|
|
|
|
|
|
|
assert num_cpus > 0
|
|
|
|
|
|
|
|
self.voltage_domain = VoltageDomain(voltage=cpu_voltage)
|
|
|
|
self.clk_domain = SrcClockDomain(clock=cpu_clock,
|
|
|
|
voltage_domain=self.voltage_domain)
|
|
|
|
|
|
|
|
self.cpus = [ self._cpu_type(cpu_id=system.numCpus() + idx,
|
|
|
|
clk_domain=self.clk_domain)
|
|
|
|
for idx in range(num_cpus) ]
|
|
|
|
|
|
|
|
for cpu in self.cpus:
|
|
|
|
cpu.createThreads()
|
|
|
|
cpu.createInterruptController()
|
|
|
|
cpu.socket_id = system.numCpuClusters()
|
|
|
|
system.addCpuCluster(self, num_cpus)
|
|
|
|
|
|
|
|
def requireCaches(self):
|
|
|
|
return self._cpu_type.require_caches()
|
|
|
|
|
|
|
|
def memoryMode(self):
|
|
|
|
return self._cpu_type.memory_mode()
|
|
|
|
|
|
|
|
def addL1(self):
|
|
|
|
for cpu in self.cpus:
|
|
|
|
l1i = None if self._l1i_type is None else self._l1i_type()
|
|
|
|
l1d = None if self._l1d_type is None else self._l1d_type()
|
|
|
|
iwc = None if self._wcache_type is None else self._wcache_type()
|
|
|
|
dwc = None if self._wcache_type is None else self._wcache_type()
|
|
|
|
cpu.addPrivateSplitL1Caches(l1i, l1d, iwc, dwc)
|
|
|
|
|
|
|
|
def addL2(self, clk_domain):
|
|
|
|
if self._l2_type is None:
|
|
|
|
return
|
|
|
|
self.toL2Bus = L2XBar(width=64, clk_domain=clk_domain)
|
|
|
|
self.l2 = self._l2_type()
|
|
|
|
for cpu in self.cpus:
|
|
|
|
cpu.connectAllPorts(self.toL2Bus)
|
|
|
|
self.toL2Bus.master = self.l2.cpu_side
|
|
|
|
|
|
|
|
def connectMemSide(self, bus):
|
|
|
|
bus.slave
|
|
|
|
try:
|
|
|
|
self.l2.mem_side = bus.slave
|
|
|
|
except AttributeError:
|
|
|
|
for cpu in self.cpus:
|
|
|
|
cpu.connectAllPorts(bus)
|
|
|
|
|
|
|
|
|
|
|
|
class AtomicCluster(CpuCluster):
|
|
|
|
def __init__(self, system, num_cpus, cpu_clock, cpu_voltage="1.0V"):
|
|
|
|
cpu_config = [ CpuConfig.get("atomic"), None, None, None, None ]
|
|
|
|
super(AtomicCluster, self).__init__(system, num_cpus, cpu_clock,
|
|
|
|
cpu_voltage, *cpu_config)
|
|
|
|
def addL1(self):
|
|
|
|
pass
|
|
|
|
|
|
|
|
|
2016-07-21 18:19:16 +02:00
|
|
|
class SimpleSystem(LinuxArmSystem):
|
|
|
|
cache_line_size = 64
|
|
|
|
|
2016-09-15 19:00:59 +02:00
|
|
|
def __init__(self, **kwargs):
|
|
|
|
super(SimpleSystem, self).__init__(**kwargs)
|
2016-07-21 18:19:16 +02:00
|
|
|
|
2016-09-15 19:00:59 +02:00
|
|
|
self.voltage_domain = VoltageDomain(voltage="1.0V")
|
|
|
|
self.clk_domain = SrcClockDomain(clock="1GHz",
|
|
|
|
voltage_domain=Parent.voltage_domain)
|
2016-07-21 18:19:16 +02:00
|
|
|
|
2016-09-15 19:00:59 +02:00
|
|
|
self.realview = VExpress_GEM5_V1()
|
2016-07-21 18:19:16 +02:00
|
|
|
|
2016-09-15 19:00:59 +02:00
|
|
|
self.gic_cpu_addr = self.realview.gic.cpu_addr
|
|
|
|
self.flags_addr = self.realview.realview_io.pio_addr + 0x30
|
2016-07-21 18:19:16 +02:00
|
|
|
|
2016-09-15 19:00:59 +02:00
|
|
|
self.membus = MemBus()
|
2016-07-21 18:19:16 +02:00
|
|
|
|
2016-09-15 19:00:59 +02:00
|
|
|
self.intrctrl = IntrControl()
|
|
|
|
self.terminal = Terminal()
|
|
|
|
self.vncserver = VncServer()
|
2016-07-21 18:19:16 +02:00
|
|
|
|
2016-09-15 19:00:59 +02:00
|
|
|
self.iobus = IOXBar()
|
|
|
|
# CPUs->PIO
|
|
|
|
self.iobridge = Bridge(delay='50ns')
|
|
|
|
# Device DMA -> MEM
|
|
|
|
self.dmabridge = Bridge(delay='50ns',
|
|
|
|
ranges=self.realview._mem_regions)
|
|
|
|
|
|
|
|
self._pci_devices = 0
|
|
|
|
self._clusters = []
|
|
|
|
self._num_cpus = 0
|
2016-07-21 18:19:16 +02:00
|
|
|
|
|
|
|
def attach_pci(self, dev):
|
|
|
|
dev.pci_bus, dev.pci_dev, dev.pci_func = (0, self._pci_devices + 1, 0)
|
|
|
|
self._pci_devices += 1
|
|
|
|
self.realview.attachPciDevice(dev, self.iobus)
|
|
|
|
|
|
|
|
def connect(self):
|
|
|
|
self.iobridge.master = self.iobus.slave
|
|
|
|
self.iobridge.slave = self.membus.master
|
|
|
|
|
|
|
|
self.dmabridge.master = self.membus.slave
|
|
|
|
self.dmabridge.slave = self.iobus.master
|
|
|
|
|
|
|
|
self.gic_cpu_addr = self.realview.gic.cpu_addr
|
|
|
|
self.realview.attachOnChipIO(self.membus, self.iobridge)
|
|
|
|
self.realview.attachIO(self.iobus)
|
|
|
|
self.system_port = self.membus.slave
|
2016-09-15 19:00:59 +02:00
|
|
|
|
|
|
|
def numCpuClusters(self):
|
|
|
|
return len(self._clusters)
|
|
|
|
|
|
|
|
def addCpuCluster(self, cpu_cluster, num_cpus):
|
|
|
|
assert cpu_cluster not in self._clusters
|
|
|
|
assert num_cpus > 0
|
|
|
|
self._clusters.append(cpu_cluster)
|
|
|
|
self._num_cpus += num_cpus
|
|
|
|
|
|
|
|
def numCpus(self):
|
|
|
|
return self._num_cpus
|
|
|
|
|
|
|
|
def addCaches(self, need_caches, last_cache_level):
|
|
|
|
if not need_caches:
|
|
|
|
# connect each cluster to the memory hierarchy
|
|
|
|
for cluster in self._clusters:
|
|
|
|
cluster.connectMemSide(self.membus)
|
|
|
|
return
|
|
|
|
|
|
|
|
cluster_mem_bus = self.membus
|
|
|
|
assert last_cache_level >= 1 and last_cache_level <= 3
|
|
|
|
for cluster in self._clusters:
|
|
|
|
cluster.addL1()
|
|
|
|
if last_cache_level > 1:
|
|
|
|
for cluster in self._clusters:
|
|
|
|
cluster.addL2(cluster.clk_domain)
|
|
|
|
if last_cache_level > 2:
|
|
|
|
max_clock_cluster = max(self._clusters,
|
|
|
|
key=lambda c: c.clk_domain.clock[0])
|
|
|
|
self.l3 = L3(clk_domain=max_clock_cluster.clk_domain)
|
|
|
|
self.toL3Bus = L2XBar(width=64)
|
|
|
|
self.toL3Bus.master = self.l3.cpu_side
|
|
|
|
self.l3.mem_side = self.membus.slave
|
|
|
|
cluster_mem_bus = self.toL3Bus
|
|
|
|
|
|
|
|
# connect each cluster to the memory hierarchy
|
|
|
|
for cluster in self._clusters:
|
|
|
|
cluster.connectMemSide(cluster_mem_bus)
|