26f14d6b5d
Use EDID when available to configure the frame buffer driver with good settings for the attached display. Change-Id: I69a78155a93e55ffa1ca3ff6621a879a56cdbceb
188 lines
4.4 KiB
C
188 lines
4.4 KiB
C
/*
|
|
* Handle reading the EDID information, validating it, and parsing it into
|
|
* a struct edid_info. EDID reads are done using the Block Device Protocol
|
|
* as it's already supported by the cat24c256 driver and there is no need
|
|
* to add yet another message format/type.
|
|
*/
|
|
|
|
#include <minix/fb.h>
|
|
#include <minix/chardriver.h>
|
|
#include <minix/drivers.h>
|
|
#include <minix/ds.h>
|
|
#include <minix/rs.h>
|
|
#include <minix/log.h>
|
|
#include <minix/sysutil.h>
|
|
#include <minix/type.h>
|
|
#include <minix/vm.h>
|
|
#include <sys/ioc_fb.h>
|
|
#include <assert.h>
|
|
#include <sys/ioctl.h>
|
|
#include <sys/mman.h>
|
|
#include <errno.h>
|
|
#include <string.h>
|
|
#include <stdio.h>
|
|
#include <stdlib.h>
|
|
#include <stdint.h>
|
|
#include <dev/videomode/videomode.h>
|
|
#include <dev/videomode/edidvar.h>
|
|
#include <dev/videomode/edidreg.h>
|
|
|
|
#include "fb_edid.h"
|
|
#include "fb.h"
|
|
|
|
static int do_read(endpoint_t endpt, uint8_t *buf, size_t bufsize);
|
|
|
|
/* logging - use with log_warn(), log_info(), log_debug(), log_trace() */
|
|
static struct log log = {
|
|
.name = "edid",
|
|
.log_level = LEVEL_INFO,
|
|
.log_func = default_log
|
|
};
|
|
|
|
/*
|
|
* Labels corresponding to drivers which provide EDID.
|
|
*/
|
|
static char edid_providers[FB_DEV_NR][RS_MAX_LABEL_LEN+1];
|
|
|
|
/*
|
|
* Populate edid_providers from command line arguments. The service command
|
|
* should get EDID providers like this: "-args edid.0=tda19988.1.3470" where
|
|
* 0 is the minor number of the frame buffer, tda19988 is the device driver,
|
|
* 1 is the i2c bus and 3470 is the slave address (the TDA19988 has 2 slave
|
|
* addresses 0x34 and 0x70).
|
|
*/
|
|
int
|
|
fb_edid_args_parse(void)
|
|
{
|
|
int i;
|
|
int r;
|
|
char key[32];
|
|
|
|
for (i = 0; i < FB_DEV_NR; i++) {
|
|
|
|
memset(key, '\0', 32);
|
|
snprintf(key, 32, "edid.%d", i);
|
|
|
|
memset(edid_providers[i], '\0', RS_MAX_LABEL_LEN);
|
|
r = env_get_param(key, edid_providers[i], RS_MAX_LABEL_LEN);
|
|
if (r == OK) {
|
|
log_debug(&log, "Found key:%s value:%s\n", key, edid_providers[i]);
|
|
} else {
|
|
/* not an error, user is allowed to omit EDID
|
|
* providers in order to skip EDID reading and use
|
|
* the default settings.
|
|
*/
|
|
log_debug(&log, "Couldn't find key:%s\n", key);
|
|
}
|
|
}
|
|
|
|
return OK;
|
|
}
|
|
|
|
/*
|
|
* Send a read request to the block driver at endpoint endpt.
|
|
*/
|
|
static int
|
|
do_read(endpoint_t driver_endpt, uint8_t *buf, size_t bufsize)
|
|
{
|
|
int r;
|
|
message m;
|
|
cp_grant_id_t grant_nr;
|
|
|
|
/* Open Device - required for drivers using libblockdriver */
|
|
memset(&m, '\0', sizeof(message));
|
|
m.m_type = BDEV_OPEN;
|
|
m.BDEV_ACCESS = R_BIT;
|
|
m.BDEV_ID = 0;
|
|
m.BDEV_MINOR = 0;
|
|
|
|
r = sendrec(driver_endpt, &m);
|
|
if (r != OK) {
|
|
log_debug(&log, "sendrec(BDEV_OPEN) failed (r=%d)\n", r);
|
|
return r;
|
|
}
|
|
|
|
grant_nr = cpf_grant_direct(driver_endpt, (vir_bytes) buf,
|
|
bufsize, CPF_READ | CPF_WRITE);
|
|
|
|
/* Perform the read */
|
|
memset(&m, '\0', sizeof(message));
|
|
m.m_type = BDEV_READ;
|
|
m.BDEV_MINOR = 0;
|
|
m.BDEV_COUNT = bufsize;
|
|
m.BDEV_GRANT = grant_nr;
|
|
m.BDEV_FLAGS = BDEV_NOPAGE; /* the EEPROMs used for EDID are pageless */
|
|
m.BDEV_ID = 0;
|
|
m.BDEV_POS_LO = 0;
|
|
m.BDEV_POS_HI = 0;
|
|
|
|
r = sendrec(driver_endpt, &m);
|
|
cpf_revoke(grant_nr);
|
|
if (r != OK) {
|
|
log_debug(&log, "sendrec(BDEV_READ) failed (r=%d)\n", r);
|
|
/* Clean-up: try to close the device */
|
|
memset(&m, '\0', sizeof(message));
|
|
m.m_type = BDEV_CLOSE;
|
|
m.BDEV_MINOR = 0;
|
|
m.BDEV_ID = 0;
|
|
sendrec(driver_endpt, &m);
|
|
return r;
|
|
}
|
|
|
|
/* Close the device */
|
|
memset(&m, '\0', sizeof(message));
|
|
m.m_type = BDEV_CLOSE;
|
|
m.BDEV_MINOR = 0;
|
|
m.BDEV_ID = 0;
|
|
r = sendrec(driver_endpt, &m);
|
|
if (r != OK) {
|
|
log_debug(&log, "sendrec(BDEV_CLOSE) failed (r=%d)\n", r);
|
|
return r;
|
|
}
|
|
|
|
return bufsize;
|
|
}
|
|
|
|
int
|
|
fb_edid_read(int minor, struct edid_info *info)
|
|
{
|
|
|
|
int r;
|
|
uint8_t buffer[128];
|
|
endpoint_t endpt;
|
|
|
|
if (info == NULL || minor < 0 || minor >= FB_DEV_NR ||
|
|
edid_providers[minor][0] == '\0') {
|
|
return EINVAL;
|
|
}
|
|
|
|
log_debug(&log, "Contacting %s to get EDID.\n", edid_providers[minor]);
|
|
|
|
/* Look up the endpoint that corresponds to the label */
|
|
endpt = 0;
|
|
r = ds_retrieve_label_endpt(edid_providers[minor], &endpt);
|
|
if (r != 0 || endpt == 0) {
|
|
log_warn(&log, "Couldn't find endpoint for label '%s'\n", edid_providers[minor]);
|
|
return r;
|
|
}
|
|
|
|
/* Perform the request and put the resulting EDID into the buffer. */
|
|
memset(buffer, 0x00, 128);
|
|
r = do_read(endpt, buffer, 128);
|
|
if (r < 0) {
|
|
log_debug(&log, "Failed to read EDID\n");
|
|
return r;
|
|
}
|
|
|
|
/* parse and validate EDID */
|
|
r = edid_parse(buffer, info);
|
|
if (r != 0) {
|
|
log_warn(&log, "Invalid EDID data in buffer.\n");
|
|
return r;
|
|
}
|
|
|
|
log_debug(&log, "EDID Retrieved and Parsed OK\n");
|
|
|
|
return OK;
|
|
}
|
|
|