TTY: select and revive with new notify and FS call back;
kernel: removed old notify code; removed ugly prepare_shutdown timer
kputc: don't send to FS if PRINTF_PROC fails
- SIGKMESS: new kernel message (sent to TTY, IS, or LOG)
- SIGKSTOP: MINIX is shut down (sent to TTY-> switch to primary console)
- SIGKSIG: kernel signals pending (sent to PM)
Renamed SYS_SETPRIORITY to SYS_NICE.
Cleaned up system call library.
Added new alert() trap to replace notify() --- current notify will be removed
and alert() will be called notify() later.
and the new log driver if enabled.
new usyslogd is started from /usr/etc/rc. New device created by
MAKEDEV.sh. /var/log created by etc/mtree/minix.tree (on root for
now). Made select() slightly more generic, with less code duplication.
The TTY driver now only notifies the IS server about function key event,
but does not tell which keys are pressed. The IS servers queries the TTY
driver to find out about this.
need /tmp any more since 16MB root device; increase to 3.0.5 to make new
CD with working FXP driver. (not tagged 3.0.5 yet as at driver bios-copy
workaround hasn't been done.)
* Removed some variants of the SYS_GETINFO calls from the kernel;
replaced them with new PM and utils libary functionality. Fixed
bugs in utils library that used old get_kenv() variant.
* Implemented a buffer in the kernel to gather random data.
Memory driver periodically checks this for /dev/random.
A better random algorithm can now be implemented in the driver.
Removed SYS_RANDOM; the SYS_GETINFO call is used instead.
* Remove SYS_KMALLOC from the kernel. Memory allocation can now
be done at the process manager with new 'other' library functions.
names. All system processes can now either use panic() or report() from
libutils, or redefine their own function. Assertions are done via the standard
<assert.h> functionality.
This allowed removing the p_flagarlm timer from the kernel's process table.
Furthermore, I merged p_syncalrm and p_signalrm into p_alarm_timer to save
even more space. Note that processes can no longer have both a signal and
synchronous alarm timer outstanding as of now.