gem5/tests/configs/memtest.py
Dam Sunwoo 230540e655 mem: fix cache stats to use request ids correctly
This patch fixes the cache stats to use the new request ids.
Cache stats also display the requestor names in the vector subnames.
Most cache stats now include "nozero" and "nonan" flags to reduce the
amount of excessive cache stat dump. Also, simplified
incMissCount()/incHitCount() functions.
2012-02-12 16:07:39 -06:00

93 lines
2.9 KiB
Python

# Copyright (c) 2006-2007 The Regents of The University of Michigan
# All rights reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions are
# met: redistributions of source code must retain the above copyright
# notice, this list of conditions and the following disclaimer;
# redistributions in binary form must reproduce the above copyright
# notice, this list of conditions and the following disclaimer in the
# documentation and/or other materials provided with the distribution;
# neither the name of the copyright holders nor the names of its
# contributors may be used to endorse or promote products derived from
# this software without specific prior written permission.
#
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
# "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
# LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
# A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
# OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
# SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
# LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
# DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
# THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
# (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
# OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
#
# Authors: Ron Dreslinski
import m5
from m5.objects import *
# --------------------
# Base L1 Cache
# ====================
class L1(BaseCache):
latency = '1ns'
block_size = 64
mshrs = 12
tgts_per_mshr = 8
is_top_level = True
# ----------------------
# Base L2 Cache
# ----------------------
class L2(BaseCache):
block_size = 64
latency = '10ns'
mshrs = 92
tgts_per_mshr = 16
write_buffers = 8
#MAX CORES IS 8 with the fals sharing method
nb_cores = 8
cpus = [ MemTest() for i in xrange(nb_cores) ]
# system simulated
system = System(cpu = cpus, funcmem = PhysicalMemory(),
physmem = PhysicalMemory(),
membus = Bus(clock="500GHz", width=16))
# l2cache & bus
system.toL2Bus = Bus(clock="500GHz", width=16)
system.l2c = L2(size='64kB', assoc=8)
system.l2c.cpu_side = system.toL2Bus.port
# connect l2c to membus
system.l2c.mem_side = system.membus.port
# add L1 caches
for cpu in cpus:
cpu.l1c = L1(size = '32kB', assoc = 4)
cpu.l1c.cpu_side = cpu.test
cpu.l1c.mem_side = system.toL2Bus.port
system.funcmem.port = cpu.functional
system.system_port = system.membus.port
# connect memory to membus
system.physmem.port = system.membus.port
# -----------------------
# run simulation
# -----------------------
root = Root( full_system = False, system = system )
root.system.mem_mode = 'timing'
#root.trace.flags="Cache CachePort MemoryAccess"
#root.trace.cycle=1