Commit graph

32 commits

Author SHA1 Message Date
Pierre-Yves Péneau a854373d59 mem, stats: fix typos in CommMonitor and Stats
Signed-off-by: Pierre-Yves Péneau <pierre-yves.peneau@lirmm.fr>
Reviewed-by: Tony Gutierrez <anthony.gutierrez@amd.com>
Reviewed-by: Jason Lowe-Power <jason@lowepower.com>
Signed-off-by: Jason Lowe-Power <jason@lowepower.com>

Reviewed at http://reviews.gem5.org/r/3802/
2017-02-15 14:59:06 -06:00
Pierre-Yves Péneau a06a46f5d1 mem, misc: fix building issue with CommMonitor (unused variables)
Signed-off-by: Pierre-Yves Péneau <pierre-yves.peneau@lirmm.fr>
Reviewed-by: Andreas Hansson <andreas.hansson@arm.com>
Reviewed-by: Jason Lowe-Power <jason@lowepower.com>
Signed-off-by: Jason Lowe-Power <jason@lowepower.com>

Reviewed at http://reviews.gem5.org/r/3801/
2017-02-15 14:56:54 -06:00
Rahul Thakur e9889c46ed mem: Refactor CommMonitor stats, add basic atomic mode stats
Signed-off-by: Jason Lowe-Power <jason@lowepower.com>
2017-01-27 14:58:16 -06:00
Brandon Potter 7a8dda49a4 style: [patch 1/22] use /r/3648/ to reorganize includes 2016-11-09 14:27:37 -06:00
Stephan Diestelhorst 589033c94c sim: Call regStats of base-class as well
We want to extend the stats of objects hierarchically and thus it is necessary
to register the statistics of the base-class(es), as well.  For now, these are
empty, but generic stats will be added there.

Patch originally provided by Akash Bagdia at ARM Ltd.
2016-06-06 17:16:43 +01:00
Andreas Hansson 0fcb376e5f mem: Make cache terminology easier to understand
This patch changes the name of a bunch of packet flags and MSHR member
functions and variables to make the coherency protocol easier to
understand. In addition the patch adds and updates lots of
descriptions, explicitly spelling out assumptions.

The following name changes are made:

* the packet memInhibit flag is renamed to cacheResponding

* the packet sharedAsserted flag is renamed to hasSharers

* the packet NeedsExclusive attribute is renamed to NeedsWritable

* the packet isSupplyExclusive is renamed responderHadWritable

* the MSHR pendingDirty is renamed to pendingModified

The cache states, Modified, Owned, Exclusive, Shared are also called
out in the cache and MSHR code to make it easier to understand.
2015-12-31 09:32:58 -05:00
Andreas Hansson 2a1f49fae6 mem: Pass snoop retries through the CommMonitor
Allow the monitor to be placed after a snooping port, and do not fail
on snoop retries, but instead pass them on to the slave port.
2015-10-14 13:32:28 -04:00
Andreas Hansson 9a0129dcbf mem: Add PacketInfo to be used for packet probe points
This patch fixes a use-after-delete issue in the packet probe points
by adding a PacketInfo struct to retain the key fields before passing
the packet onwards. We want to probe the packet after it is
successfully sent, but by that time the fields may be modified, and
the packet may even be deleted.

Amazingly enough the issue has gone undetected for months, and only
recently popped up in our regressions.
2015-09-25 13:25:34 -04:00
Andreas Sandberg a3f49f60c7 mem: Move trace functionality from the CommMonitor to a probe
This changeset moves the access trace functionality from the
CommMonitor into a separate probe. The probe can be hooked up to any
component that exports probe points of the type ProbePoints::Packet.

This patch moves the dependency on Google's Protocol Buffers library
from the CommMonitor to the MemTraceProbe, which means that the
CommMonitor (including stack distance profiling) no long depends on
it.
2015-08-04 10:29:13 +01:00
Andreas Sandberg 022e69e6de mem: Redesign the stack distance calculator as a probe
This changeset removes the stack distance calculator hooks from the
CommMonitor class and implements a stack distance calculator as a
memory system probe instead. The probe can be hooked up to any
component that exports probe points of the type ProbePoints::Packet.
2015-08-04 10:29:13 +01:00
Andreas Sandberg feded87fc9 mem: Add probe support to the CommMonitor
This changeset adds a standardized probe point type to monitor packets
in the memory system and adds two probe points to the CommMonitor
class. These probe points enable monitoring of successfully delivered
requests and successfully delivered responses.

Memory system probe listeners should use the BaseMemProbe base class
to provide a unified configuration interface and reuse listener
registration code. Unlike the ProbeListenerObject class, the
BaseMemProbe allows objects to be wired to multiple ProbeManager
instances as long as they use the same probe point name.
2015-08-04 10:29:13 +01:00
Andreas Sandberg 777cc71c4a mem: Cleanup CommMonitor in preparation for probe support
Make configuration parameters constant and get rid of an unnecessary
dependency on the Time class.
2015-07-06 17:08:53 +01:00
Geoffrey Blake 1d403960af mem: Enable CommMonitor to output traces in atomic mode
The CommMonitor by default only allows memory traces to be gathered in
timing mode. This patch allows memory traces to be gathered in atomic
mode if all one needs is a functional trace of memory addresses used
and timing information is of a secondary concern.
2015-03-19 04:06:10 -04:00
Andreas Hansson f26a289295 mem: Split port retry for all different packet classes
This patch fixes a long-standing isue with the port flow
control. Before this patch the retry mechanism was shared between all
different packet classes. As a result, a snoop response could get
stuck behind a request waiting for a retry, even if the send/recv
functions were split. This caused message-dependent deadlocks in
stress-test scenarios.

The patch splits the retry into one per packet (message) class. Thus,
sendTimingReq has a corresponding recvReqRetry, sendTimingResp has
recvRespRetry etc. Most of the changes to the code involve simply
clarifying what type of request a specific object was accepting.

The biggest change in functionality is in the cache downstream packet
queue, facing the memory. This queue was shared by requests and snoop
responses, and it is now split into two queues, each with their own
flow control, but the same physical MasterPort. These changes fixes
the previously seen deadlocks.
2015-03-02 04:00:35 -05:00
Kanishk Sugand 7a25b1a0e0 mem: Add stack distance statistics to the CommMonitor
This patch adds the stack distance calculator to the CommMonitor. The
stats are disabled by default.
2014-12-23 09:31:18 -05:00
Andreas Hansson de62aedabc misc: Fix a bunch of minor issues identified by static analysis
Add some missing initialisation, and fix a handful benign resource
leaks (including some false positives).
2014-09-27 09:08:29 -04:00
Nilay Vaish d07abd9b5b mem: change the namespace Message to ProtoMessage
The namespace Message conflicts with the Message data type used extensively
in Ruby.  Since Ruby is being moved to the same Master/Slave ports based
configuration style as the rest of gem5, this conflict needs to be resolved.
Hence, the namespace is being renamed to ProtoMessage.
2014-09-01 16:55:46 -05:00
Sascha Bischoff e940bac278 mem: Auto-generate CommMonitor trace file names
Splits the CommMonitor trace_file parameter into three parameters. Previously,
the trace was only enabled if the trace_file parameter was set, and would be
written to this file. This patch adds in a trace_enable and trace_compress
parameter to the CommMonitor.

No trace is generated if trace_enable is set to False. If it is set to True, the
trace is written to a file based on the name of the SimObject in the simulation
hierarchy. For example, system.cluster.il1_commmonitor.trc. This filename can be
overridden by additionally specifying a file name to the trace_file parameter
(more on this later).

The trace_compress parameter will append .gz to any filename if set to True.
This enables compression of the generated traces. If the file name already ends
in .gz, then no changes are made.

The trace_file parameter will override the name set by the trace_enable
parameter. In the case that the specified name does not end in .gz but
trace_compress is set to true, .gz is appended to the supplied file name.
2014-05-09 18:58:46 -04:00
Sascha Bischoff 548d47ea2c mem: CommMonitor trace warn on non-timing mode
Add a warning to the CommMonitor which will alert the user if they try
and record a trace when the system is not in timing mode.
2014-03-23 11:11:40 -04:00
Andreas Hansson c9cb492e1c mem: Fix input to DPRINTF in CommMonitor
Minor fix of the debug message parameters.
2014-02-18 05:50:51 -05:00
Andreas Hansson d4273cc9a6 mem: Set the cache line size on a system level
This patch removes the notion of a peer block size and instead sets
the cache line size on the system level.

Previously the size was set per cache, and communicated through the
interconnect. There were plenty checks to ensure that everyone had the
same size specified, and these checks are now removed. Another benefit
that is not yet harnessed is that the cache line size is now known at
construction time, rather than after the port binding. Hence, the
block size can be locally stored and does not have to be queried every
time it is used.

A follow-on patch updates the configuration scripts accordingly.
2013-07-18 08:31:16 -04:00
Andreas Hansson f25ea3fd56 mem: Fix CommMonitor style and response check
This patch fixes the CommMonitor local variable names, and also
introduces a variable to capture if it expects to see a response. The
latter check considers both needsResponse and memInhibitAsserted.
2013-06-27 05:49:49 -04:00
Andreas Hansson 7a57b1bce0 mem: Add optional request flags to the packet trace
This patch adds an optional flags field to the packet trace to encode
the request flags that contain information about whether the request
is (un)cacheable, instruction fetch, preftech etc.
2013-03-26 14:46:44 -04:00
Andreas Hansson 0622f30961 mem: Add predecessor to SenderState base class
This patch adds a predecessor field to the SenderState base class to
make the process of linking them up more uniform, and enable a
traversal of the stack without knowing the specific type of the
subclasses.

There are a number of simplifications done as part of changing the
SenderState, particularly in the RubyTest.
2013-02-19 05:56:05 -05:00
Andreas Hansson 9947923c60 mem: Ensure trace captures packet fields before forwarding
This patch fixes a bug in the CommMonitor caused by the packet being
modified before it is captured in the trace. By recording the fields
before passing the packet on, and then putting these values in the
trace we ensure that even if the packet is modified the trace captures
what the CommMonitor saw.
2013-02-19 05:56:05 -05:00
Andreas Hansson f456c7983d mem: Add tracing support in the communication monitor
This patch adds packet tracing to the communication monitor using a
protobuf as the mechanism for creating the trace.

If no file is specified, then the tracing is disabled. If a file is
specified, then for every packet that is successfully sent, a protobuf
message is serialized to the file.
2013-01-07 13:05:37 -05:00
Nilay Vaish 2d6470936c sim: have a curTick per eventq
This patch adds a _curTick variable to an eventq. This variable is updated
whenever an event is serviced in function serviceOne(), or all events upto
a particular time are processed in function serviceEvents(). This change
helps when there are eventqs that do not make use of curTick for scheduling
events.
2012-11-16 10:27:47 -06:00
Andreas Hansson 2a740aa096 Port: Add protocol-agnostic ports in the port hierarchy
This patch adds an additional level of ports in the inheritance
hierarchy, separating out the protocol-specific and protocl-agnostic
parts. All the functionality related to the binding of ports is now
confined to use BaseMaster/BaseSlavePorts, and all the
protocol-specific parts stay in the Master/SlavePort. In the future it
will be possible to add other protocol-specific implementations.

The functions used in the binding of ports, i.e. getMaster/SlavePort
now use the base classes, and the index parameter is updated to use
the PortID typedef with the symbolic InvalidPortID as the default.
2012-10-15 08:12:35 -04:00
Andreas Hansson 46d9adb68c Port: Make getAddrRanges const
This patch makes getAddrRanges const throughout the code base. There
is no reason why it should not be, and making it const prevents adding
any unintentional side-effects.
2012-07-09 12:35:34 -04:00
Andreas Hansson 830391cad9 Port: Add getAddrRanges to master port (asking slave port)
This patch adds getAddrRanges to the master port, and thus avoids
going through getSlavePort to be able to ask the slave. Similar to the
previous patch that added isSnooping to the SlavePort, this patch aims
to introduce an additional level of hierarchy in the ports (base port
being protocol-agnostic) and getSlave/MasterPort will return port
pointers to these base classes.

The function is named getAddrRanges also on the master port, but does
nothing besides asking the connected slave port. The slave port, as
before, has to provide an implementation and actually produce a list
of address ranges. The initial design used the name getSlaveAddrRanges
for the new function, but the more verbose name was later changed.
2012-07-09 12:35:33 -04:00
Andreas Hansson 49407d76aa Port: Add isSnooping to slave port (asking master port)
This patch adds isSnooping to the slave port, and thus avoids going
through getMasterPort to be able to ask the master. Over the course of
the next few patches, all getMasterPort/getSlavePort in Port and
MemObject are to be protocol agnostic, and the snooping is part of the
protocol layer.

The function is already present on the master port, where it is
implemented by the module itself, e.g. a cache. On the slave side, it
is merely asking the connected master port. The same name is used by
both functions despite their difference in behaviour. The initial
design used isMasterSnooping on the slave port side, but the more
verbose function name was later changed.
2012-07-09 12:35:32 -04:00
Andreas Hansson ab23e29487 MEM: Add the communication monitor
This patch adds a communication monitor MemObject that can be inserted
between a master and slave port to provide a range of statistics about
the communication passing through it. The communication monitor is
non-invasive and does not change any properties or timing of the
packets, with the exception of adding a sender state to be able to
track latency. The statistics are only collected in timing mode (not
atomic) to avoid slowing down any fast forwarding.

An example of the statistics captured by the monitor are: read/write
burst lengths, bandwidth, request-response latency, outstanding
transactions, inter transaction time, transaction count, and address
distribution. The monitor can be used in combination with periodic
resetting and dumping of stats (through schedStatEvent) to study the
behaviour over time.

In future patches, a selection of convenience scripts will be added to
aid in visualising the statistics collected by the monitor.
2012-05-09 04:37:45 -04:00