Change the device latency here to a latency rather than a Tick

src/python/m5/objects/Device.py:
src/python/m5/objects/Pci.py:
    Change the default here to a latency rather than a Tick

--HG--
extra : convert_revision : b9366dd89646cea27a836baf249ac2da38c1809f
This commit is contained in:
Ali Saidi 2006-07-19 17:24:20 -04:00
parent fe9e851e8c
commit a50c5cc999
2 changed files with 2 additions and 2 deletions

View file

@ -12,7 +12,7 @@ class BasicPioDevice(PioDevice):
type = 'BasicPioDevice'
abstract = True
pio_addr = Param.Addr("Device Address")
pio_latency = Param.Tick(1, "Programmed IO latency in simticks")
pio_latency = Param.Latency('1ns', "Programmed IO latency in simticks")
class DmaDevice(PioDevice):
type = 'DmaDevice'

View file

@ -52,7 +52,7 @@ class PciDevice(DmaDevice):
pci_bus = Param.Int("PCI bus")
pci_dev = Param.Int("PCI device number")
pci_func = Param.Int("PCI function code")
pio_latency = Param.Tick(1, "Programmed IO latency in simticks")
pio_latency = Param.Latency('1ns', "Programmed IO latency in simticks")
configdata = Param.PciConfigData(Parent.any, "PCI Config data")
class PciFake(PciDevice):